Terminal crimping terminal machine of commonly used in the operation, it has very strict technical standards, mainly including: pulled off force size, symmetry, line pressure meet in the middle of the both sides have a bell mouth, wire core pressure it without aperture, bottom can't pressure Angle, etc.
1. Purpose:
- check the base member for terminal image.
- visual inspection method is applicable.
- not sure about the ambiguity.
- reproducibility of measurement (determination experiment) is not suitable.
2. Problem points (projects):
- there is no reference component for bellMouth.
- section status check benchmark components.
1)FLASH is too large and FLASH biased.
2) void fraction.
3)BARREL asymmetry.
4)BARRELSIZE due to excessive interference (bottom, side)
3. The countermeasures:
- set inspection standards and protocols for each project.
- increase the set inspection benchmark for joint use.
- applicable relevant data (TEST related data)
4. Add the setting benchmark:
-bellmouth has, no benchmark setting append benchmark.
- additional setting of inspection datum of section status.
1)FLASH is too large and FLASH biased.
2) void fraction.
3)BARREL asymmetry.
4)BARRELSIZE interferes (bottom, side) due to excessive size